1.
J Arthroplasty ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38677343

RESUMO

INTRODUCTION: Periprosthetic joint infection (PJI) treatment has high failure rates even after two-stage revision. Risk factors for treatment failure after staged revision for PJI are not well defined, nor is it well established how they correlate with the risks of developing an index PJI. Identifying modifiable risk factors may allow preoperative optimization, while identifying non-modifiable risk factors can influence surgical options or advise against further surgery. We performed a systematic review and meta-analysis to better define predictors of treatment failure in two-stage revision for PJI. METHODS: The Pubmed, Embase, and Scopus databases were searched from their inception in December 1976 to April 15, 2023. Studies comparing patient-related variables between patients successfully treated who had two-staged revision total hip arthroplasty and patients with persistent infections were included. Studies were screened, and two independent reviewers extracted data, while a third resolved discrepancies. Meta-analysis was performed on these data. There were 10,052 unique studies screened, and 21 studies met the inclusion criteria for data extraction. RESULTS: There was good-quality evidence that obesity, liver cirrhosis, and previous failed revisions for PJI are non-modifiable risk factors, while intravenous drug use and smoking are modifiable risk factors for treatment failure after two-stage revision for hip PJI. Reoperation between revision stages was also significantly associated with an increased risk of treatment failure. Interestingly, other risk factors for an index PJI including male gender, American Society of Anaesthesiology score, diabetes mellitus and inflammatory arthropathy did not predict treatment failure. Evidence on Charlson Comorbidity Index was limited. DISCUSSION: Patients with a smoking history, obesity, intravenous drug use, previous failed revision for PJI, reoperation between stages and LC are more likely to experience TF after two-stage revision THA for PJI. Modifiable risk factors include smoking and IVDU and these patients should be referred to services for cessation as early as possible before two-stage revision THA.

2.
Bone Joint J ; 106-B(5 Supple B): 74-81, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688495

RESUMO

Aims: The aim of this study was to compare the biomechanical models of two frequently used techniques for reconstructing severe acetabular defects with pelvic discontinuity in revision total hip arthroplasty (THA) - the Trabecular Metal Acetabular Revision System (TMARS) and custom triflange acetabular components (CTACs) - using virtual modelling. Methods: Pre- and postoperative CT scans from ten patients who underwent revision with the TMARS for a Paprosky IIIB acetabular defect with pelvic discontinuity were retrospectively collated. Computer models of a CTAC implant were designed from the preoperative CT scans of these patients. Computer models of the TMARS reconstruction were segmented from postoperative CT scans using a semi-automated method. The amount of bone removed, the implant-bone apposition that was achieved, and the restoration of the centre of rotation of the hip were compared between all the actual TMARS and the virtual CTAC implants. Results: The median amount of bone removed for TMARS reconstructions was significantly greater than for CTAC implants (9.07 cm3 (interquartile range (IQR) 5.86 to 21.42) vs 1.16 cm3 (IQR 0.42 to 3.53) (p = 0.004). There was no significant difference between the median overall implant-bone apposition between TMARS reconstructions and CTAC implants (54.8 cm2 (IQR 28.2 to 82.3) vs 56.6 cm2 (IQR 40.6 to 69.7) (p = 0.683). However, there was significantly more implant-bone apposition within the residual acetabulum (45.2 cm2 (IQR 28.2 to 72.4) vs 25.5 cm2 (IQR 12.8 to 44.1) (p = 0.001) and conversely significantly less apposition with the outer cortex of the pelvis for TMARS implants compared with CTAC reconstructions (0 cm2 (IQR 0 to 13.1) vs 23.2 cm2 (IQR 16.4 to 30.6) (p = 0.009). The mean centre of rotation of the hip of TMARS reconstructions differed by a mean of 11.1 mm (3 to 28) compared with CTAC implants. Conclusion: In using TMARS, more bone is removed, thus achieving more implant-bone apposition within the residual acetabular bone. In CTAC implants, the amount of bone removed is minimal, while the implant-bone apposition is more evenly distributed between the residual acetabulum and the outer cortex of the pelvis. The differences suggest that these implants used to treat pelvic discontinuity might achieve short- and long-term stability through different biomechanical mechanisms.


Assuntos
Acetábulo , Artroplastia de Quadril , Prótese de Quadril , Desenho de Prótese , Reoperação , Tantálio , Tomografia Computadorizada por Raios X , Humanos , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Feminino , Masculino , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Fenômenos Biomecânicos , Idoso de 80 Anos ou mais , Falha de Prótese , Porosidade
3.
Artigo em Inglês | MEDLINE | ID: mdl-38546666

RESUMO

BACKGROUND: Lower doses of irradiation (≤ 5 Mrad) during the manufacture of highly crosslinked polyethylene acetabular liners may result in less crosslinking and an increased wear rate. Radiostereometric analysis (RSA) studies have found that wear of more highly irradiated highly crosslinked polyethylene liners (7 to 10 Mrad) decreases at longer-term follow-up compared with earlier reports of the same cohorts. Although wear of 5-Mrad irradiated liners appears to increase at midterm follow-up, it is unclear whether that remains true at longer follow-up. QUESTIONS/PURPOSES: We asked: (1) In patients who underwent THA with a 5-Mrad highly crosslinked polyethylene liner, what is the wear rate evaluated with RSA during the first 14 years? (2) Does the wear rate decrease after 6 years in situ? METHODS: This is a brief follow-up of prior RSA studies performed at 2 and 6 years. We prospectively reviewed the longer-term wear rate in 13 patients who underwent primary THAs with the same design of a 5-MRad irradiated crosslinked acetabular liner and a 28-mm cobalt-chromium articulation. Of the initial 30 patients who were enrolled, 13 (43%) were available at the 14-year timepoint; nine patients had died, 1 patient had withdrawn, 1 had an intraoperative fracture, 3 patients were too infirm to have radiographs, 2 had no baseline RSA radiographs, and 1 had poor-quality RSA images. Tantalum markers were inserted during surgery, and all patients had RSA radiographic examinations at 1 week, 6 months, and 1, 2, 6, and 14 years postoperatively. RESULTS: The mean ± standard deviation proximal, 2D, and 3D wear rates calculated between 1 year and 14 years were 0.019 ± 0.013 mm, 0.022 ± 0.015 mm, and 0.025 ± 0.019 mm per year, respectively. No patient had proximal 2D or 3D wear rates exceeding 0.06 mm per year. An increasing wear rate over time was measured for proximal and 2D wear rates between 6 and 14 years (0.024 and 0.030 mm per year) compared with that between 1 and 6 years (0.008 and 0.010 mm per year; p = 0.03). CONCLUSION: The proximal, 2D, and 3D wear of a highly crosslinked polyethylene liner produced using 5-Mrad radiation remains low in the longer-term. With the small numbers available in a long-term RSA study such as this, we confirmed that the wear rate did not decrease at longer-term follow-up, unlike previous RSA studies of more highly irradiated highly crosslinked polyethylene liners. Nevertheless, the wear rate remains very low and below the threshold typically associated with the development of osteolysis (0.1 mm/year of wear). This should provide assurance to orthopaedic surgeons monitoring patients with this 5-Mrad irradiated liner in situ, while providing useful information to manufacturers of future highly crosslinked polyethylene liners. LEVEL OF EVIDENCE: Level IV therapeutic study.

4.
J Orthop Res ; 42(2): 373-384, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37526382

RESUMO

While finite element (FE) models have been used extensively in orthopedic studies, validation of their outcome metrics has been limited to comparison against ex vivo testing. The aim of this study was to validate FE model predictions of the initial cup mechanical environment against patient-matched in vivo measurements of acetabular cup migration using radiostereometric analysis (RSA). Tailored musculoskeletal and FE models were developed using a combination of three-dimensional (3D) motion capture data and clinical computerized tomography (CT) scans for a cohort of eight individuals who underwent primary total hip replacement and were prospectively enrolled in an RSA study. FE models were developed to calculate the mean modulus of cancellous bone, composite peak micromotion (CPM), composite peak strain (CPS) and percentage area of bone ingrowth. The RSA cup migration at 3 months was used to corroborate the FE output metrics. Qualitatively, all FE-predicted metrics followed a similar rank order as the in vivo RSA 3D migration data. The two cases with the lowest predicted CPM (<20 µm), lowest CPS (<0.0041), and high bone modulus (>917 MPa) were confirmed to have the lowest in vivo RSA 3D migration (<0.14 mm). The two cases with the largest predicted CPM (>80 µm), larger CPS (>0.0119) and lowest bone modulus (<472 MPa) were confirmed to have the largest in vivo RSA 3D migration (>0.78 mm). This study enabled the first corroboration between tailored musculoskeletal and FE model predictions with in vivo RSA cup migration. Investigation of additional patient-matched CT, gait, and RSA examinations may allow further development and validation of FE models.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Análise Radioestereométrica/métodos , Análise de Elementos Finitos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/métodos
5.
Acta Orthop ; 94: 626-634, 2023 12 29.
Artigo em Inglês | MEDLINE | ID: mdl-38157007

RESUMO

BACKGROUND AND PURPOSE: We conducted a systematic review and meta-analysis of RSA studies to investigate the early and long-term migration patterns of acetabular cups and the influence of implant factors on cup migration over time. METHODS: We performed a systematic search of PubMed, Embase, and Scopus databases to identify all RSA studies of cup migration following primary total hip replacement (THR). Proximal migration at 3 and 6 months, 1, 2, 5, and 10 years were considered for analysis. Implant factors investigated included fixation type, head size, bearing surface, uncemented coating design, and the decade of RSA introduction. RESULTS: 47 studies reported the proximal migration of 83 cohorts (2,328 cups). Besides 1 threaded cup design, no implant factor investigated was found to significantly influence proximal migration. The mean pooled 2-year proximal migration of cemented cups (0.14 mm, 95% confidence interval [CI] 0.08-0.20) was not significantly different from uncemented cups (0.12 mm, CI 0.04-0.19). The mean pooled proximal migration at 6 months was 0.11 mm (CI 0.06-0.16) and there was no significant increase between 6 months and 2 years (0.015 mm, CI 0.000-0.030). 27 of 75 cohorts (36%) reported mean proximal migration greater than 0.2 mm at 2 years, which has previously been identified as a predictor of implants at risk of long-term loosening. CONCLUSION: Our meta-analysis demonstrated that the majority of cup migration occurs within the first 6 months. With one exception, no implant factors influenced the 2-year proximal migration of acetabular cups. 36% of studies with 2-year migration were considered at risk of long-term loosening. Further investigation and comparison against long-term survivorship data would validate 6-month and/or 1-year proximal migration measurements as an earlier predictor of long-term loosening than the current 2-year threshold.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Prótese de Quadril/efeitos adversos , Seguimentos , Artroplastia de Quadril/efeitos adversos , Acetábulo/cirurgia , Reoperação , Falha de Prótese , Desenho de Prótese
6.
Bone Jt Open ; 4(11): 839-845, 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37926113

RESUMO

Aims: Radiostereometric analysis (RSA) is the most accurate radiological method to measure in vivo wear of highly cross-linked polyethylene (XLPE) acetabular components. We have previously reported very low wear rates for a sequentially irradiated and annealed X3 XLPE liner (Stryker Orthopaedics, USA) when used in conjunction with a 32 mm femoral heads at ten-year follow-up. Only two studies have reported the long-term wear rate of X3 liners used in conjunction with larger heads using plain radiographs which have poor sensitivity. The aim of this study was to measure the ten-year wear of thin X3 XLPE liners against larger 36 or 40 mm articulations with RSA. Methods: We prospectively reviewed 19 patients who underwent primary cementless THA with the XLPE acetabular liner (X3) and a 36 or 40 mm femoral head with a resultant liner thickness of at least 5.8 mm. RSA radiographs at one week, six months, and one, two, five, and ten years postoperatively and femoral head penetration within the acetabular component were measured with UmRSA software. Of the initial 19 patients, 12 were available at the ten-year time point. Results: The median proximal, 2D, and 3D wear rates calculated between one and ten years were all less than 0.005 mm/year, with no patient recording a proximal wear rate of more than 0.021 mm/year. Importantly, there was no increase in the wear rate between five and ten years. Conclusion: The very low wear rate of X3 XLPE liners with larger articulations remains encouraging for the future clinical performance of this material.

7.
J Arthroplasty ; 38(12): 2716-2723.e1, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37321515

RESUMO

BACKGROUND: There are ongoing concerns regarding the use of bone graft following prosthetic joint infection and subsequent implant subsidence. The aim of this study was to determine whether the use of a cemented stem combined with femoral impaction bone grafting (FIBG) at second stage revision for infection results in stable femoral stem fixation, determined by accurate methods, and good clinical results. METHODS: A prospective cohort of 29 patients underwent staged revision total hip arthroplasty for infection using an interval prosthesis followed by FIBG at the final reconstruction. The mean follow-up was 89 months (range, 8 to 167 months). Femoral implant subsidence was measured with radiostereometric analysis. Clinical outcomes included the Harris Hip Score, Harris Pain score and Société Internationale de Chirurgie Orthopédique et de Traumatologie activity scores. RESULTS: At 2-years follow-up the median stem subsidence relative to femur was -1.36 mm (range, -0.31 to -4.98), while the cement subsidence relative to femur was -0.05 mm (range, 0.36 to -0.73). At 5-years follow-up, the median stem subsidence relative to femur was -1.89 mm (range, -0.27 to -6.35), while the cement subsidence relative to femur was -0.06 mm (range, 0.44 to -0.55). There were 25 patients who were confirmed infection-free after the second stage revision with FIBG. The median Harris Hip Score improved from 51 pre-operatively to 79 at 5 years (P = .0130), and Harris Pain score from 20 to 40 (P = .0038). CONCLUSIONS: Stable femoral component fixation can be achieved with FIBG when reconstructing the femur after revision for infection without compromising infection cure rates and patient-reported outcomes.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Análise Radioestereométrica , Prótese de Quadril/efeitos adversos , Seguimentos , Transplante Ósseo/métodos , Estudos Prospectivos , Desenho de Prótese , Fêmur/cirurgia , Reoperação/métodos , Cimentos Ósseos , Dor/cirurgia , Falha de Prótese
8.
Acta Orthop ; 94: 191-199, 2023 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-37114317

RESUMO

BACKGROUND AND PURPOSE: Assessing peri-acetabular bone quality is valuable for optimizing the outcomes of primary total hip arthroplasty (THA) as preservation of good quality bone stock likely affects implant stability. The aim of this study was to perform a meta-analysis of peri-acetabular bone mineral density (BMD) changes over time measured using quantitative computer tomography (CT) and, second, to investigate the influence of age, sex, and fixation on the change in BMD over time. METHODS: A systematic search of Embase, Scopus, Web of Science, and PubMed databases identified 19 studies that measured BMD using CT following THA. The regions of interest (ROI), reporting of BMD results, and scan protocols were extracted. A meta-analysis of BMD was performed on 12 studies that reported measurements immediately postoperatively and at follow-up. RESULTS: The meta-analysis determined that periacetabular BMD around both cemented and uncemented components decreases over time. The amount of BMD loss increased relative to proximity of the acetabular component. There was a greater decrease in cortical BMD over time in females and cancellous BMD for young patients of any sex. CONCLUSION: Peri-acetabular BMD decreases at different rates relative to its proximity to the acetabular component. Cancellous BMD decreases more in young patients and cortical bone decreases more in females. Standardized reporting parameters and suggested ROI to measure peri-acetabular BMD are proposed, to enable comparison between implant and patient variables in the future.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteoartrite do Quadril , Feminino , Humanos , Masculino , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Densidade Óssea , Prótese de Quadril/efeitos adversos , Absorciometria de Fóton , Seguimentos , Osteoartrite do Quadril/cirurgia , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Tomografia Computadorizada por Raios X
9.
J Orthop Res ; 41(3): 657-662, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35652835

RESUMO

Metal artifact reduction (MAR) has improved computed tomography (CT) imaging of total hip arthroplasty (THA) but the assessment of osteolysis and implant to bone contact relies on the accurate depiction of bone defects, cancellous bone, and cement. This study evaluates the impact of available single and dual-energy protocols on periprosthetic tissue characterization in a cadaveric phantom. Bilateral THA was performed on a fresh frozen cadaveric pelvis with simulated osteolytic cavities. CT acquisitions with projection-based MAR and noise equivalence were performed using single energy 140 kVp, single energy 150 kVp with 0.6 mm tin filtration, and dual-energy at 100/150 kVp with 0.6 mm tin filtration, from which simulated energies were extracted. Image subtraction, segmentation, region of interest histograms, and line profiles were used to characterize tissue density and separation. Tissue densities were heavily dependent on the energy profile of the protocol. Cancellous bone ranged from 182 to 45 HU and cement from 1012 to 131 HU using 140 kVp compared to dual-energy with weighted high energy tube, respectively. Spectral separation between cancellous bone, osteolytic defect, and cement was reduced for all protocols compared with 140 kVp. Spectral overlap was most severe using dual-energy with heavily weighted high-energy tubes. Dual-energy algorithms reduced trabecular contrast within the cancellous bone and cortical edge response. Although the dual-energy acquisition has been proposed as an additive to projection-based MAR techniques in THA, reduced density and contrast in clinically relevant periprosthetic tissue compared to 140 kVp single energy may limit its use in characterizing periprosthetic tissues.


Assuntos
Artroplastia de Quadril , Humanos , Artefatos , Estanho , Tomografia Computadorizada por Raios X/métodos , Cadáver , Imagens de Fantasmas , Algoritmos
10.
J Biomech ; 144: 111275, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36063585

RESUMO

Postoperative weight bearing has the potential to generate fragmental motion of surgically repaired tibial plateau fractures (TPFs), which may contribute to loss of fracture reduction. The effect of loading on the internal distribution of fragmentary displacements is currently unknown. The aim of this study was to determine the internal displacements of surgically repaired split TPFs due to a three-bodyweight load, using large-volume micro-CT imaging and image correlation. Fractures were generated and surgically repaired for two cadaveric specimens. Load was applied to the specimens inside a large-volume micro-CT system and scanned at 0.046 mm isotropic voxel size. Pre- and post-loading images were paired, co-registered, and internal fragmentary displacements quantified. Internal fragmental displacements of the cadaveric bones were compared to in vivo displacements measured in the lateral split fragments of TPFs in a clinical cohort of patients who had similar surgical repair and were prescribed pain tolerated postoperative weight bearing. The split fragments of cadaveric specimens displaced, on average, less than 0.3 mm, consistent with in vivo measurements. Specimen one rotated around the mediolateral axis, while specimen two displaced consistently caudally. Specimen two also had varying displacements along the mediolateral axis where, at the fracture site, the fragment displaced caudally and laterally, while the most lateral edge of the tibial plateau displaced caudally and medially. The methods applied in this study can be used to measure internal fragmental motion within TPFs.


Assuntos
Fixação Interna de Fraturas , Fraturas da Tíbia , Humanos , Fixação Interna de Fraturas/métodos , Microtomografia por Raio-X , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Suporte de Carga , Cadáver
11.
Clin Orthop Relat Res ; 480(3): 485-491, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34596603

RESUMO

BACKGROUND: The introduction of crosslinked ultra-high molecular weight polyethylene (XLPE) acetabular liners has been very successful, with decreased wear and reduction in the rates of revision hip arthroplasties. XLPE is the preferred articulation for most surgeons; however, there are concerns about the long-term performance of XLPE liners created with different manufacturing processes, which may lead to time-dependent failure, including accelerated wear, after several years. QUESTIONS/PURPOSES: (1) What is the amount and rate of wear during the first 10 years using radiostereometric analysis (RSA) measurements of patients who had THAs that included a second-generation XLPE bearing? (2) Does the rate of wear change after 5 years in situ? METHODS: This is a brief follow-up of a previous RSA study. In that study, we prospectively enrolled 21 patients with osteoarthritis who underwent primary cementless THA with an XLPE acetabular liner (three cycles of 3Mrad annealed) and 32-mm articulation. That group represented 44% of the 48 THAs performed by the surgeon at the hospital where RSA was available; 16 had cemented hips, leaving 32 who were invited to participate in this study. Of those, 11 lived rurally and declined to participate, leaving 21 patients who were included in the initial study. Since then, three patients died, one developed dementia and could not participate, and one had revision THA for reasons other than wear, leaving 16 patients available for analysis at 10 years. Tantalum markers were inserted during surgery, and all patients had RSA radiographs taken at 1 week, 6 months, and 1, 2, 5, and 10 years postoperatively. Femoral head penetration into the acetabular component was measured with RSA, including bedding-in during the first year and annual wear thereafter. RESULTS: The median medial, proximal, anterior, two-dimensional (2D), and three-dimensional (3D) wear rates between 1 and 10 years were -0.001, 0.004, -0.012, 0.000, and 0.002 mm/year, respectively. No patient in this cohort had a proximal or 2D wear rate greater than 0.025 mm/year. The median proximal wear rate between 5 and 10 years (0.002 mm/year) was not greater than wear at 1 to 5 years (0.004 mm/year). CONCLUSION: Femoral head penetration in this second-generation XLPE liner remained very low at 10 years and accelerated wear after 5 years in situ did not occur. Concerns about late-onset wear from oxidation of irradiated-annealed XLPE were not observed. The low level of wear remains encouraging for the future clinical performance of this material. LEVEL OF EVIDENCE: Level II, therapeutic study.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Polietilenos , Desenho de Prótese , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Análise Radioestereométrica , Fatores de Tempo
12.
J Am Acad Orthop Surg ; 29(14): 591-595, 2021 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-34161958

RESUMO

Long-stemmed uncemented implants are commonly used during revision hip arthroplasty but may be difficult to re-revise. Impaction bone grafting allows for the use of a shorter cemented stem during revision hip arthroplasty and may restore bone stock in patients with substantial femoral defects. Femoral impaction bone grafting is particularly beneficial in younger patients, who are more likely to require additional revision procedures in the future. The surgical technique used at our institution includes improvements to previous methods including the use of modular tamps and nonirradiated, size-profiled bone graft.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cimentos Ósseos , Transplante Ósseo , Humanos , Falha de Prótese , Reoperação
13.
J Clin Med ; 11(1)2021 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-35011863

RESUMO

Periprosthetic joint infection (PJI) is a serious complication of total hip arthroplasty. Staged revision surgery is considered effective in eradicating PJI. We aimed to determine the rate of infection resolution after each stage of staged revision surgery (first stage, repeat first stage, second stage, excision arthroplasty, and reimplantation) and to assess functional outcomes and the mortality rate at ten years in a consecutive series of 30 chronic PJI of total hip arthroplasties. Infection resolution was defined as no clinical nor laboratory evidence of infection at 24 months after the last surgery and after a minimum of 12 months following cessation of antimicrobial treatment. Four patients died within 24 months of their final surgery. Nineteen patients, 73% (worst-case analysis (wca) 63%), were infection free after 1 surgery; 22 patients, 85% (wca 73%), were infection free after 2 surgeries; and 26 patients, 100% (wca 87%), were infection free after three and four surgeries. The median Harris Hip Score was 41 prior to first revision surgery and improved to 74 at twelve months and 76 at ten years after the final surgery. Thirteen patients died at a mean of 64 months from first revision, giving a mortality rate of 43% at ten years, which is approximately 25% higher than that of an age-matched general population. The results show that with repeated aggressive surgical treatment, most PJIs of the hip are curable. Ten years after successful treatment of PJI, functional outcomes and pain are improved and maintained compared to before initial surgery, but this must be balanced against the high 10-year mortality. Level of evidence: cohort studies.

14.
J Clin Med ; 9(11)2020 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-33114372

RESUMO

There is currently no accurate data on fracture displacement during the rehabilitation of pelvic ring injuries. This study investigated the use of radiostereometric analysis (RSA) in assessing the stability of C1 pelvic ring injuries stabilised with a posterior plate and an anterior external fixator. Six patients, instructed to weight-bear as tolerated after surgery, were reviewed at 2, 4, 6, 12, 26, 52 and 104 weeks. The external fixators were removed at 6 weeks. Outcomes, including the Iowa Pelvic Score (IPS), and complications were recorded. Fracture stability was assessed using measurements on plain radiographs and RSA. All patients progressed to full weight-bearing without support within 6 weeks. At 104 weeks, the IPS was excellent in four patients, good in one patient and fair in one patient. Plain radiographs showed that all fractures were well reduced, and no loss of reduction occurred over time. By contrast, RSA measurements identified displacement in all cases. The maximum three-dimensional (3D) displacement at any time point in each patient ranged from 2 to 10 mm. Two patients with the largest displacement over time had the lowest IPS. RSA also demonstrated displacements above the currently defined normal threshold through the 'un-injured' sacroiliac joint in the same two patients, suggesting a subtle C2 injury, missed at initial assessment. This study demonstrates the limitations of plain radiographs in assessing pelvic fracture stability and displacement during healing, and the potential of RSA to monitor more accurately the effects of stabilisation and weight-bearing on fracture stability.

15.
J Arthroplasty ; 35(10): 2931-2937, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32593487

RESUMO

BACKGROUND: It is proposed that highly porous coatings on acetabular components, such as a porous tantalum coating, provide adequate fixation without ancillary screw fixation in primary total hip arthroplasty (THA). However, tantalum acetabular components have been associated with higher rates of revision than other uncemented components in national registries. The aim of this randomized controlled trial is to determine whether the early migration of a solid-backed tantalum acetabular component was no greater than that of a titanium acetabular component with ancillary screw fixation that has proven good clinical results. METHODS: Sixty-six patients aged 40 to 64 years, with osteoarthritis and Charnley grade A or B activity grade and who underwent primary THA, were recruited into the trial. Patients were randomized intraoperatively to receive either the tantalum or titanium acetabular component. All patients received the same cemented polished tapered femoral stem, 28-mm cobalt-chromium femoral head, and highly cross-linked polyethylene liner. Acetabular component migration was measured using radiostereometric analysis at 4-6 days postoperatively and at 6 weeks, 3 months, 1 and 2 years following THA. RESULTS: The mean proximal migration at 2 years for the tantalum cohort was 0.17 mm (95% confidence interval, 0.09-0.24) which was no greater than that of the titanium cohort which was 0.19 mm (0.07-0.32). Harris hip scores and functional activity scores were similar between groups. CONCLUSION: These results demonstrate that early stability can be achieved without ancillary screw fixation through the use of a highly porous high friction coating on a solid-backed modular acetabular component. LEVEL OF EVIDENCE: Level I.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/cirurgia , Adulto , Parafusos Ósseos , Seguimentos , Humanos , Pessoa de Meia-Idade , Porosidade , Desenho de Prótese , Falha de Prótese , Reoperação , Tantálio , Titânio
16.
JBJS Rev ; 8(4): e0170, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32304493

RESUMO

* Radiostereometric analysis (RSA) studies of acetabular component migration following revision total hip arthroplasty (THA) have a large variation in their methodology and reporting of results, and, therefore, they may not be directly comparable. Standardization of RSA reporting is recommended. * In our review of RSA studies, there was a trend for cemented acetabular components to have larger amounts of early proximal migration than uncemented acetabular components. Results regarding cemented and uncemented components should be reported separately. * Cohorts that addressed larger acetabular defects were associated with a larger amount of early migration. * Reporting the migration result at 1 and 2 years postoperatively may enable earlier identification of poorly performing implants.


Assuntos
Acetábulo/diagnóstico por imagem , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Reoperação/efeitos adversos , Artroplastia de Quadril/instrumentação , Humanos , Análise Radioestereométrica
17.
J Clin Med ; 9(3)2020 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-32110908

RESUMO

Tibial plateau fractures (TPFs) are challenging, requiring complex open reduction and internal fixation (ORIF) and are often associated with complications including surgical site infections (SSIs). In 2007, we introduced a novel management protocol to treat TPFs which consisted of an angiosome- or perforator-sparing (APS) anterolateral approach followed by unrestricted weight bearing and range of motion. The primary aim of this retrospective study was to investigate complication rates and patient outcomes associated with our new management protocol. In total, 79 TPFs treated between 2004 and 2007 through a classic anterolateral surgical approach formed the "Classic Group"; while 66 TPFS treated between 2007 and 2013 formed the "APS Group". Fracture reduction, maintenance of reduction and patient-reported outcomes were assessed. There was a clinically important improvement in the infection incidence with the APS (1.5%) versus the Classic technique (7.6%) (1/66 versus 2/79 for superficial infections; 0/66 versus 4/79 for deep infections). Despite a more aggressive rehabilitation, there was no difference in the fracture reduction over time or the functional outcomes between both groups (p > 0.05). The APS anterolateral approach improved the rate of SSIs after TPFs without compromising fracture reduction and stabilisation. We continue to use this new management approach and early unrestricted weight bearing when treating amenable TPFs.

18.
J Orthop Res ; 38(7): 1497-1505, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32039492

RESUMO

Radiostereometric analysis (RSA) is the most accurate method of measuring component migration using radiographs but is restricted to use in prospective studies. Ein-Bild-Roentgen-analyze (EBRA)-Cup can be used retrospectively, but its accuracy to measure component migration following revision is unknown. This study aimed to determine the accuracy of EBRA-Cup measurements of uncemented acetabular component migration after revision total hip replacement (THR). The secondary aim was to compare the number of cases identified using EBRA-Cup and RSA as having proximally migrated above and below 1 mm at 2 years postoperatively. EBRA-Cup measurements were performed on plain antero-posterior pelvic radiographs taken at the same time as RSA radiographs in a prospective cohort of 53 hips undergoing acetabular revision. At 2 years, the mean difference between the RSA and EBRA-Cup measurements for 17 components used to treat pelvic discontinuity was 0.90 mm, significantly greater than the mean difference of 0.28 mm for 36 components without discontinuity (P = .0001). The mean difference between the RSA and EBRA-Cup measurements at 2 years for hips that were reconstructed with an acetabular component alone, 0.28 mm, was significantly lower than hips that were reconstructed with an acetabular component in combination with an augment and/or cage, 0.74 mm (P = .0005). In conclusion, EBRA-Cup can accurately measure migration of uncemented acetabular components used at revision THR. The presence of pelvic discontinuity, and addition of augments and cages, significantly influenced the accuracy of EBRA-Cup measurements. EBRA-Cup and RSA had good agreement on classification of components that migrated proximally above or below 1 mm at 2 years, with 100% sensitivity, and 87% specificity.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Falha de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Radioestereométrica
19.
J Arthroplasty ; 34(7): 1430-1434, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30956048

RESUMO

BACKGROUND: The aim of this study is to assess the outcomes of 52 consecutive Vancouver B2 peri-prosthetic fractures around cemented polished double-tapered stems treated by open reduction and internal fixation in 2 trauma centers in 2 countries. METHODS: Outcomes included modified Harris Hip Score (mHHS), Harris Pain Score, and return to pre-injury mobility. Fracture healing was assessed; implant subsidence measured and complications including re-operations reported. RESULTS: No patient was lost to follow-up. Median patient age at operation was 82 years (range 43-98); Harris pain scores showed minimal pain (median 42, range 10-44) at latest follow-up. Median total subsidence at 1 year was 1.1 mm (range 0-5.4), the majority of which occurred within the cement mantle. No subsequent femoral stem revision was required (median 2.9 years, 0-10); however, there were 3 re-operations: 1 re-operation for pre-existing recurrent dislocation involving head liner exchange and 2 for repeat fixation due to metal fatigue. Two additional fractures occurred below the new plating, requiring further plating whilst still retaining the original stems. CONCLUSION: Anatomical reduction and open reduction and internal fixation of Vancouver B2 peri-prosthetic fractures should be considered as an appropriate treatment solution for frail elderly patients with a peri-prosthetic fracture around cemented polished double-tapered stems.


Assuntos
Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas , Fraturas Periprotéticas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Cimentos Ósseos , Feminino , Fêmur/cirurgia , Consolidação da Fratura , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas Periprotéticas/etiologia , Reoperação/estatística & dados numéricos , Estudos Retrospectivos
20.
J Bone Joint Surg Am ; 100(22): 1926-1933, 2018 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-30480597

RESUMO

BACKGROUND: The acetabular components used in revision total hip arthroplasty (THA) to treat severe acetabular bone defects have high rates of re-revision at mid to long-term follow-up. Early translation of acetabular components used in revision THA is a good predictor of later loosening, and radiostereometric analysis (RSA) is the most sensitive method to measure migration. The objectives of the present study were to use RSA to compare the migration of the porous tantalum acetabular components used to treat severe bone defects with the previously established acceptable proximal translation threshold of ≤1 mm within 2 years, and to determine the effect on migration of the addition of inferior screws through the component into the ischium or pubis. METHODS: RSA was utilized to measure the migration of 55 porous tantalum components used to treat severe acetabular defects (28 Paprosky IIIA, 27 Paprosky IIIB; 21 hips with pelvic discontinuity) at a mean follow-up of 4 years (range, 2 to 12 years). RESULTS: Forty-eight of the 55 components migrated less than the threshold that predicts later loosening (>1 mm) and 50 had not been re-revised at the time of the latest follow-up. Seven components, none of which had inferior screw fixation, exceeded the translation threshold. Of these, 6 were implanted to treat pelvic discontinuity. Of those 6 components, 5 were re-revised for loosening related to patient symptoms. At 2 years, the absolute median proximal translation of components with inferior screw fixation was |0.3| mm (range, |0.1| to |0.9| mm), compared with |0.4| mm (range, |0.03| to |16.4| mm) for those without inferior screws (p = 0.04). CONCLUSIONS: As measured with use of RSA, the majority of porous tantalum acetabular components used in a revision THA to treat severe acetabular defects had acceptable early migration. This predicts good long-term survivorship of these components. The use of inferior screws further improved acetabular component fixation. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril , Doenças Ósseas/cirurgia , Migração de Corpo Estranho/diagnóstico por imagem , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Reoperação , Tantálio , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Porosidade , Estudos Prospectivos , Análise Radioestereométrica , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS